Security Camera System: Complete Wiring Guide
Bill of materials
Modern IP camera systems use Power over Ethernet (PoE): one Cat6 cable carries both data and power to each camera, up to 328 ft (100 m) per run. Buy solid copper Cat6, not copper-clad aluminum (CCA): CCA has higher resistance, so it runs hotter and drops more voltage when it carries power. Cat6 usually has thicker conductors (23 AWG) than Cat5e (24 AWG), which also helps on long PoE runs. Outside, use cable with a sunlight-resistant outdoor jacket; underground, use direct-burial rated cable or outdoor-rated cable in conduit. The NVR or PoE switch needs a standard 120V outlet.
PoE camera cable is a Class 2 power-limited circuit (NEC Article 725). Indoors, use cable listed for the space it runs through (plenum-rated CMP in air-handling spaces). Do not run it in the same box or raceway as line-voltage wiring unless a listed barrier separates them (725.136). Some states license low-voltage installers separately; check with your state licensing board.
Camera cabling: Cat6 and PoE
As an Amazon Associate we earn from qualifying purchases.
NVR/POE switch power
| Component | Specification | NEC basis |
|---|---|---|
| Wire (copper) | 14 AWG THHN | Table 310.16, 110.14(C) |
| Wire (aluminum alt.) | 12 AWG THHN | Table 310.16, 110.14(C) |
| Breaker | 15A single-pole | 240.4 |
| Voltage | 120V single-phase | |
| Conduit (EMT) | 1/2" EMT | Chapter 9 Table 4 |
| Max distance (3% VD) | 191 ft at 120V copper | 210.19(A) Note 4 |
Installation notes
GFCI is not specifically required for this application by NEC, though local amendments may differ. Check with your local building department before starting work.
Standard 120V circuits use NM-B cable with 14/2 cable (hot, neutral, ground). For conduit runs, pull individual 14 AWG THHN conductors. All connections must be made in accessible junction boxes.
Run length matters: every foot of wire adds voltage drop, reducing power to your equipment. The table below shows the exact voltage drop at common distances. If your run exceeds the 3% threshold, upsize one gauge.
Voltage drop by distance
Percentage voltage drop at common run lengths. NEC recommends 3% maximum for branch circuits and 5% for combined feeder plus branch.
| Distance | 14 AWG Co | 12 AWG Al | 12 AWG Co |
|---|---|---|---|
| 25 ft | 0.4% | 0.4% | 0.2% |
| 50 ft | 0.8% | 0.8% | 0.5% |
| 75 ft | 1.2% | 1.2% | 0.7% |
| 100 ft | 1.6% | 1.6% | 1.0% |
| 150 ft | 2.4% | 2.4% | 1.5% |
| 200 ft | 3.1% | 3.2% | 2.0% |
Related wire data
Detailed ampacity: 14 AWG copper, 12 AWG aluminum. Wire size lookup: 15A circuit. Calculators: voltage drop ยท panel load calculator.
Frequently asked questions
What wire size do I need for security camera system?
Use 14 AWG copper or 12 AWG aluminum on a 15A breaker at 120V. This is based on NEC 2023 Table 310.16 ampacity with 110.14(C) termination limits. The equipment nameplate or installation manual sets the minimum circuit ampacity and maximum breaker; follow it where it differs.
Does security camera system require GFCI?
No. GFCI is not required for this application.
NEC 2023 references verified February 2026 · Report a mistake