Project GuideNEC 2023 · 2026 · Updated

Security Camera System: Complete Wiring Guide

Best cable for security cameras: solid copper Cat6 PoE cable, with a sunlight-resistant outdoor jacket on exterior walls and a direct-burial rating (or conduit) underground. One cable carries data and power to each camera, up to 328 ft (100 m) per run. Avoid copper-clad aluminum (CCA) cable for PoE. The only 120V wiring is the NVR/PoE switch outlet: 14 AWG copper on a 15A breaker.
Camera cableCat6, solid copper
Max run328 ft
NVR outlet14 AWG, 15A
GFCINot required

Bill of materials

Modern IP camera systems use Power over Ethernet (PoE): one Cat6 cable carries both data and power to each camera, up to 328 ft (100 m) per run. Buy solid copper Cat6, not copper-clad aluminum (CCA): CCA has higher resistance, so it runs hotter and drops more voltage when it carries power. Cat6 usually has thicker conductors (23 AWG) than Cat5e (24 AWG), which also helps on long PoE runs. Outside, use cable with a sunlight-resistant outdoor jacket; underground, use direct-burial rated cable or outdoor-rated cable in conduit. The NVR or PoE switch needs a standard 120V outlet.

PoE camera cable is a Class 2 power-limited circuit (NEC Article 725). Indoors, use cable listed for the space it runs through (plenum-rated CMP in air-handling spaces). Do not run it in the same box or raceway as line-voltage wiring unless a listed barrier separates them (725.136). Some states license low-voltage installers separately; check with your state licensing board.

NVR/POE switch power

ComponentSpecificationNEC basis
Wire (copper)14 AWG THHNTable 310.16, 110.14(C)
Wire (aluminum alt.)12 AWG THHNTable 310.16, 110.14(C)
Breaker15A single-pole240.4
Voltage120V single-phase
Conduit (EMT)1/2" EMTChapter 9 Table 4
Max distance (3% VD)191 ft at 120V copper210.19(A) Note 4

Installation notes

GFCI is not specifically required for this application by NEC, though local amendments may differ. Check with your local building department before starting work.

Standard 120V circuits use NM-B cable with 14/2 cable (hot, neutral, ground). For conduit runs, pull individual 14 AWG THHN conductors. All connections must be made in accessible junction boxes.

Run length matters: every foot of wire adds voltage drop, reducing power to your equipment. The table below shows the exact voltage drop at common distances. If your run exceeds the 3% threshold, upsize one gauge.

Voltage drop by distance

Percentage voltage drop at common run lengths. NEC recommends 3% maximum for branch circuits and 5% for combined feeder plus branch.

Distance14 AWG Co12 AWG Al12 AWG Co
25 ft0.4%0.4%0.2%
50 ft0.8%0.8%0.5%
75 ft1.2%1.2%0.7%
100 ft1.6%1.6%1.0%
150 ft2.4%2.4%1.5%
200 ft3.1%3.2%2.0%

Detailed ampacity: 14 AWG copper, 12 AWG aluminum. Wire size lookup: 15A circuit. Calculators: voltage drop ยท panel load calculator.

Frequently asked questions

What wire size do I need for security camera system?

Use 14 AWG copper or 12 AWG aluminum on a 15A breaker at 120V. This is based on NEC 2023 Table 310.16 ampacity with 110.14(C) termination limits. The equipment nameplate or installation manual sets the minimum circuit ampacity and maximum breaker; follow it where it differs.

Does security camera system require GFCI?

No. GFCI is not required for this application.

Requirements vary by state. NEC edition, licensing, permits, and GFCI rules differ by jurisdiction. Check your state or pick it below for personalized info across WireRef.
Important: For reference only. Not a substitute for a licensed electrician. Electrical work can cause serious injury, death, fire, or property damage if performed incorrectly. Always hire a licensed electrician for electrical work, especially for service upgrades, panel work, and 240V circuits. Values are derived from NFPA 70 (NEC) for educational purposes. Always verify against your locally adopted NEC edition and amendments - local jurisdictions may enforce stricter requirements. WireRef provides reference information only and is not responsible for work performed based on this content. NEC® is a registered trademark of the National Fire Protection Association. Free NEC access via NFPA · OSHA Electrical Safety · Terms of use.

NEC 2023 references verified February 2026 · Report a mistake

As an Amazon Associate, WireRef earns from qualifying purchases. Product links do not affect the reference data or recommendations on this site. Terms of use.